Login Page - Create Account

Support Board


Date/Time: Thu, 25 Apr 2024 18:59:14 +0000



New millisecond (ms) number next to studies added to chart

View Count: 820

[2017-03-29 23:17:56]
User553714 - Posts: 184
I just updated to version 1536 and noticed that a ms number is added next to studies added to the chart; presumably this is some type of performance reading? Has this been documented and if so can you please direct me to the doc. If not can you please give a brief explanation?

If it's a run time reading is it just for the specific study code and what might it say about performance of the study if you get a reading as high as 6000ms?

NB: I have wanted some study performance reading for some time now so am glad to see it added. Regards
[2017-03-30 10:22:48]
Sierra Chart Engineering - Posts: 104368
Refer to Studies to Graph documentation here about this:
Chart Studies: Chart Studies Window

6000 milliseconds is very high.
Sierra Chart Support - Engineering Level

Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy:
https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation

For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service:
Sierra Chart Teton Futures Order Routing
[2017-03-31 02:55:32]
User553714 - Posts: 184
Thanks for the reply; I thought I would share a related experience with others. I tracked down my 6000ms recalculation time issue to having AutoLoop = 1 in my ACSIL code when the particular study didn't really need it. Turning this off reduced my recalc time to single digits. Regards

To post a message in this thread, you need to log in with your Sierra Chart account: