Login Page - Create Account

Support Board


Date/Time: Sun, 05 May 2024 17:08:09 +0000



Post From: New millisecond (ms) number next to studies added to chart

[2017-03-31 02:55:32]
User553714 - Posts: 184
Thanks for the reply; I thought I would share a related experience with others. I tracked down my 6000ms recalculation time issue to having AutoLoop = 1 in my ACSIL code when the particular study didn't really need it. Turning this off reduced my recalc time to single digits. Regards