Post From: Bollinger band study broken with Study OHLC input when using any of the BB OHLC, HLC, or HL aver

[2015-07-12 02:31:44]
i960 - Posts: 360
Sorry, the exact setting is "Use latest source data for last bar." It was added per this thread: Problem with High Accuracy Spread Chart

But was forgotten for the Ratio (single line) study. Additionally, the "Zero output when non exact data match" from Difference (bar) flag is also missing from the Ratio (bar) study.

In summary:

Ratio (single line) is missing "Use latest source data for last bar"
Ratio (bar) is missing "Zero output when non exact data match"
And presently Ratio (single line) does strange things when there is missing data and a bollinger band is used (as can be seen in the chart capture I uploaded in post 13).