Login Page - Create Account

Support Board


Date/Time: Thu, 25 Apr 2024 21:50:09 +0000



Post From: Notice: Sierra Chart/Barchart Exchange Data Feed

[2020-03-06 05:46:21]
Sierra Chart Engineering - Posts: 104368
Can i have the source instance as a simulation one and two client instances for order routing?
Yes this will work.

Just make sure you set the Source Data Multiplier Symbol Setting appropriately. If the source instance is set to SC Data-All Services , the multiplier will be the inverse of the SC Data Multiplier setting.

For example, for the ES?## in the source instance using SC Data-All Services this will be set to .01. But in the destination instance for the SC order routing service which uses symbol ES?##_FUT_CME, the Source Data Multiplier needs to be the inverse and set to 100.
Sierra Chart Support - Engineering Level

Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy:
https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation

For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service:
Sierra Chart Teton Futures Order Routing