Post From: v2922 & v2947: study calculation or replay data loading silently stops chartbook-wide during Accurate back test replay; Reca

[2026-09-11 23:31:55]
User313107 - Posts: 4
Update - isolation test per your suggestion (Safe Mode, no custom studies).

Setup: a disposable copy of the installation (2922 64-bit, same data files, a copy of the chartbook, network disabled at the OS). Same replay recipe as the earlier reports: Accurate Trading System Back Test, All Charts in Chartbook, start 2026-08-02 00:00:00, speed 100X, Skip Empty Periods off, Processing Step 1 second. Two runs on 2026-09-11, same machine, fresh program launch for each. Note the two runs were stopped at different points (details below), so the Stop conditions are not identical between them.

RUN A - normal login (custom studies loaded):
- Replay ran ~2.0 hours real time (2026-08-02 -> ~2026-08-08) with NO mid-run stall; it passed both replay points where the earlier stalls happened.
- Pressed Stop at 14:22:11 (chart local time): "Reloading chart" was logged for all 4 charts, then nothing further appeared in the message log until program exit at 14:29:55 - 7 min 44 s with no "Chart data loading complete". Charts were blank in a screenshot taken 16 s after Stop and still blank just before exit. File >> Exit closed normally.

RUN B - Safe Mode login (message log shows "Safe Mode enabled"; zero custom study / DLL lines in the log for the whole session; no custom studies computing):
- Identical replay recipe. This run was left running longer, ~3.5 hours real time (2026-08-02 -> 2026-08-09 19:41), with NO mid-run stall.
- Pressed Stop at 18:14:23: same failure - "Reloading chart" x4 logged, then nothing further in the message log until exit at 18:22:40 - 8 min 17 s with no "Chart data loading complete". Charts blank in a screenshot at 18:22:06 (7 min 43 s after Stop). Exit normal.

Answering your questions:

1) The post-Stop dead-reload reproduced in both Normal and Safe Mode - i.e. this symptom occurred without the custom studies loaded in this test. That rules out the custom studies as a required condition for THIS symptom in this trial; it does not by itself confirm the root cause.

2) The mid-run silent stall from the earlier reports (study calculation stopping at ~46 min in one run; the replay data loader freezing at ~62 min in another) did NOT occur in either run this session. It is intermittent, so we cannot yet say whether that component reproduces without custom studies.

For completeness on the reload-failure history by trigger: after Stop - run 1 (2922), run 3c (2947), and now both of these runs (2922, with and without custom studies); after a backward Jump - run 2 (2922).

One observation from these two runs (this session only): with this start time (Sunday 00:00, Skip Empty Periods off) the replay position stayed at the previous close (07-31 16:59:54) for ~28 minutes of real time before data began, then proceeded normally, in both runs. Our earlier report of the replay never leaving the start position on 2947 was stopped at 25 minutes; whether that was the same waiting behavior or a real failure is unresolved - we have not re-verified it.

Message logs and screenshots from both runs are available - happy to attach if useful.
Date Time Of Last Edit: 2026-09-11 23:36:44