Login Page - Create Account

Support Board


Date/Time: Fri, 04 Jul 2025 22:34:10 +0000



Post From: Problem when displaying TPO using 'One Period of Fixed Time Length at End' option

[2024-02-28 09:45:53]
ticinotrader - Posts: 415
Thank you for the reply John.

I am just a bit confused about what you say (rolling 30min period), because when adding the VbP study using the same parameters (One Period at End of Fixed Time Lenght, Fixed Time: Minutes, Period Length 30) to an empty 30min chart, the VbP properly and automatically resets at the start of each new 30min bar period. So it is not a rolling 30min period. It seems rolling only when added to a TPO chart.

Also, when newly adding this type of VbP, initially the VbP will match the current 30min period of the TPO, but then does not reset when a new 30min period starts, but keeps printing. That is why I thought it is somehow related to the problem I described in the initial posts.

Other than this, when double-checking the settings, I found a solution for this problem, by simply using a different Volume Graph Period Type:

The 'One Period from Most Recent Period Start to End' properly resets the VbP to follow the TPO chart's periodicity (30min) properly.
Date Time Of Last Edit: 2024-02-28 09:54:24