Support Board
Date/Time: Mon, 12 May 2025 02:51:21 +0000
Post From: Order Rejected.
[2023-05-31 15:08:36] |
David Abrahams - Posts: 17 |
I have checked setting as suggested - note I have no problem charting ESM23_FUT_CME but executing on MES23_FUT_CME. See attached error log and below text eton CME Order Routing (Order reject). Info: CME (Rejected). Text: Price must be greater than zero 'Order for id: M6EM3 has non-positive price -18.9323'. Text: Attached order. Parent: 12037. Tag: 1 Contract_20_20.twconfig. Internal Order ID: 12039. Service Order ID: 1215026. Symbol: M6EM23_FUT_CME. Account: 550S3651 | 2023-05-31 10:30:12.791 * Notice: Stop Attached Order was rejected and is being resent as a Market order. | Symbol: M6EM23_FUT_CME | TradeAccount: 550S3651 | InternalOrderID: 12039 | ServiceOrderID: 1215026 | Current Status: Error | 2023-05-31 10:30:12.791 * Order cancellation failed | Teton CME Order Routing (Order cancel reject). Info: Order cancellation failed | Order Cancel Reject. Text: This order is not in the book 'Order: 8815816516582 SenderCompID: J4S2XH'. Text: Attached order. Parent: 12037. Tag: 1 Contract_20_20.twconfig. Internal Order ID: 12039. Service Order ID: 1215026. Symbol: M6EM23_FUT_CME. Account: 550S3651 | 2023-05-31 10:30:12.928 * |
![]() ![]() |