Support Board
Date/Time: Fri, 27 Nov 2026 14:29:37 +0000
Server Time error
View Count: 300
| [2026-10-08 11:41:51] |
| User244327 - Posts: 19 |
|
I'm getting a warning that my PC clock is incorrect by 7 seconds but I am using meinberg to keep it accurate. So, marbe the Server time is incorrect???Sierra Chart’s startup check says your UTC time is 7 seconds ahead of theirs, and the notice tells you to enable their NTP client. Doing that would step a clock that is 0.14 ms from NIST toward a server that is 7 seconds behind. Include these three lines from the 07:31:51 restart, and the two checks: Local computer time in UTC: 2026-10-08 11:31:51 Server time in UTC: 2026-10-08 11:31:44 Difference reported: 7 seconds Meinberg ntpq -c rv: leap=00, stratum=2, refid=42.20.202.230 (NIST), offset=-0.143 ms Google Date header versus local UTC: +0.643 s, inside the header’s 1-second resolution I'm not going to change anything until I hear back from you Thanks,Peter |
| [2026-10-08 14:43:43] |
| John - SC Support - Posts: 48660 |
|
We are not familiar with Meinberg, so we can not say anything about that. Our server clocks are definitely correct. But given your location in Vietnam, there could be a latency that existed in getting that server time. Although 7 seconds does seem higher than what it should be. Rather than look at the information in the Message Log, we prefer that you look at the "Data Delay" information that is available in your Chart Header. This gives the difference in the time from the timestamps of the data against your local computer clock. This will give the proper information you really need. This item is prefaced with a "DD:" in the chart header. If it is not there, or not visible, then please add/adjust it so you can view this. Refer to the following: Working With Charts: Region Data Line / Chart Header If this shows a 7 second difference, then this would imply that your Meinberg NTP is not working properly. In which case, we recommend using a different NTP service, such as what we offer within Sierra Chart. But anything within a few seconds could be general latency due to your location in Vietnam and the data coming out of Chicago in the USA. For the most reliable, advanced, and zero cost futures order routing, use the Teton service: Sierra Chart Teton Futures Order Routing |
| [2026-10-08 15:58:56] |
| User244327 - Posts: 19 |
|
DD: 00:00:00.221 on MES... leave the rest to you... I think things are ok at my end
|
| [2026-10-08 16:32:18] |
| John - SC Support - Posts: 48660 |
|
Your computer time and the timestamps from the exchange are within 221 milliseconds, so you are fine.
For the most reliable, advanced, and zero cost futures order routing, use the Teton service: Sierra Chart Teton Futures Order Routing |
To post a message in this thread, you need to log in with your Sierra Chart account: