In the doc of Study Overlay - OHLC:

Use Zero Values from Source Study: When this Input is set to Yes, then zero values from the referenced source Study Subgraph with a value of zero will be ignored and will not copy to the destination OHLC bars. However, still one or more of the Open, High, Low, Close values for an output bar could be zero because it had to be initialized to 0.
Should "Yes" be "No"? Maybe a typo.

Another setting is not documented: Use Standard OHLC Subgraphs from Source Study. What is this?
[2019-04-30 18:01:40]
John - SC Support - Posts: 31159
You are correct, it should state "When this Input is set to No,...". We will correct this.

The Use Standard OHLC Subgraphs from Source Study allows you to use the Open, High, Low, and Close subgraphs from the source study (if the source study has these subgraphs). Otherwise, the study only uses the particular subgraph that is referenced in the Input Setting Chart, Study, Subgraph Reference. We will add this to the documentation.