[User Discussion] - Alarm code required for the Volatility Trend Indicator

View Count: 2062

[2013-08-03 18:00:32]
RQ - Posts: 50
Guys could you help me out with the “condition code” for the Volatility Trend Indicator. When this indicator flips I would like an alarm to go off. So I need precise code to put into the condition box.
If you need me to put the request through the additional services (technical guys I will) please just let you know. Thanks

[2013-08-03 18:34:12]
Sawtooth - Posts: 3976
Try this:

=SG5=1

When you don't know which subgraph would reveal a value that can be used in an alert formula, add the Spreadsheet Study study to see what the indicator outputs. Then compare the outputted values with the occurrence you want to use.

An easy way to visually see the alert is to add the Color Bar Based On Alert Condition study, and put the formula in its Alerts tab field, adding the ID# of the indicator:

=ID1.SG5=1