Login Page - Create Account

Support Board


Date/Time: Tue, 16 Sep 2025 04:03:21 +0000



Post From: Second instance of SC message: Service Package does not....

[2021-12-02 23:32:19]
John - SC Support - Posts: 41827
The only error we are seeing is the following in SierraChart02:
UDPListener (1508). Port 22904 | Error binding to UDP port: 22904. Windows error code 10048: Only one usage of each socket address (protocol/network address/port) is normally permitted.

Unless you are specifically doing work with UDP, you can ignore this. But, if you want to resolve it, then in the SierraChart02 instance, go to Global Settings >> Sierra Chart Server Settings and change the entry for UDP Port to a value other than 22904.

Some other items of note for SierraChart01:
- The following indicates a problem with the study sst_volume_dots:
Error loading: D:\Documents\SierraChart01\Data\sst_volume_dots.dll. File not found or may be missing SCDLLName line.

- This instance has the Current Selected Service set to SC Data - All Services, but the symbols are for the Sierra Chart Order Routing Service. Open your Chartbooks in that instance and select Edit >> Translate Symbols to Current Service in order to change the symbols to the correct ones.
For the most reliable, advanced, and zero cost futures order routing, use the Teton service:
Sierra Chart Teton Futures Order Routing